Runyes Wall Haning Toshiba Tube 70KV Dental X Ray Machine

Runyes Wall Haning Toshiba Tube 70KV Dental X Ray Machine

  • Runyes Wall Haning Toshiba Tube 70KV Dental X Ray Machine
  • Runyes Wall Haning Toshiba Tube 70KV Dental X Ray Machine
Runyes Wall Haning Toshiba Tube 70KV Dental X Ray Machine
Product Details:
Place of Origin: Ningbo, China
Brand Name: Runyes
Certification: CE/FDA/ISO
Model Number: LK-C24
Payment & Shipping Terms:
Minimum Order Quantity: 1piece
Price: Negotiable
Packaging Details: 1pc/Carton, Carton Size 90×36×36cm, N.W. 26kg, G.W. 31kg
Delivery Time: 3-7 working days
Payment Terms: T/T, , MoneyGram,RMB, L/C, D/A, D/P
Supply Ability: 2000Pieces/Month
Contact Now
Detailed Product Description
Product Name: Runyes Wall-Haning Dental Digital X Ray Machine Equipment Toshiba Tube 70KV Feature: Toshiba Tube
Rated Voltage: 70KV Focus: 0.7mm
Current Of Tube-head: 7Ma Radiation Leakage: <0.007mGy/h
High Light:

70KV Dental X Ray Machine

,

Runyes Dental X Ray Machine

,

70KV dental x ray systems

Runyes Wall-Haning Dental Digital X Ray Machine Equipment Toshiba Tube 70KV

Purpose

The dental digital x ray equipment is used for Dental oral cavity. According to different users'
requirements, there are three types: Wall Mounted, Mobile and Column x-ray models.
 
Dental digital x ray equipment Composition
X Ray machine is composed by X Ray Tube head Timer and Arms (Structure)
 
Dental digital x ray equipment  Especification´s
* Electric Discharge Protection: Class 1, B type equipment
* CE-MDD: Class IIb
* FDA: Class II, Code EHD and regulation number 872.1800
* Water Proof Protection: IPX0 (Standard Equipment)
Runyes Wall Haning Toshiba Tube 70KV Dental X Ray Machine 0
Dental digital x ray equipment's parameters

 

Rated voltage: 70KV
Electric current 9A (120V) or 4A(230V)
Frequency
50/60Hz
Focus 0.7mm
Warranty One Year
Radiation leakage <0.007mGy/h
Round Output Section Focus Skin Distance-20cm
Duty cicle
1/60

 

Beam limiting device (Circular output section)
* Distance from focus to skin: 22 cm (0.72 ft)
* Output radiation - circle diameter: Ø 60 cm (0.18 ft)
Runyes Wall Haning Toshiba Tube 70KV Dental X Ray Machine 1
Timer
* 120 or 230 VAC
* Micro-processed controller function
* Set exposure time (0.06s-2.50s) automatically though object selection.
* Manually set exposure time, range from 0.06s-2.50s.
* Set each time according table.
* Child (small), adult (big), automatical digital selection
* Low dose set during using digital sensor.
* Manual switch with 3.00 mts(9.84 ft) spring cable
* Pre-heating* time is between 0.10 and 0.30 seconds and is added individually in each equipment.
The accuracy time is
±10%
±10%.
* Required time by the tube to enable the correct radiation output, while the filament of the X-Ray tube
is pre-heating.
 
Dental digital x ray equipment Safety
* Electric
- Only the installer who must be certificate or pass on training can open the timer
and touch the Circuit.
- The power cord must be according with safety regulation and with grounding protection.
- Please make sure the power is cut off during the sterilization of the dental digital x ray equipment.
* Mechanism
- Please make sure the device won't nip the finger of patient or operator during adjusting
the position.
* Blast
- This dental digital x ray equipment  can't work in the flammable and steaming working surrounding.
* Protection Agaisnt Radiation (generally regulated by law)
- Trained personnel only are allowed to operate and use the equipment.
- During the radiation exposure the operator and patient must be allowed in the room and
must not be in contact with the Tubehead or the Beam Limiting Device.
- To reduce the unwanted effects of secondary radiation on the patient, we suggest using the
relevant leaded aprons.
* Environment
- There are some parts must been disposed in accordance with relevant laws in this
machine.
Runyes Wall Haning Toshiba Tube 70KV Dental X Ray Machine 2
Dental digital x ray equipment Maintenance
General Features
The dental digital x ray equipmentrequires proper operation, periodic maintenance and servicing. The following
precautions will ensure safe and effective functioning of the system.
Periodic maintenance consists of system checks directly performed by the operator and or by
Technical Service.
Checks directly affected by the operator/technician are:
* Check that labels are intact and properly secured
* Check that Tubehead is free from oil residues
* Check that standard, coiled cable, X-Ray button is not broken or worn out
* Check for external damage in the Tubehead, which may prejudice protection
against radiation
* Check arm balancing
* Check centering of the X-Ray Bean
Checks should be performed before any operation session. In case of irregularities,
The operator shall contact Technical Service.
 

 

 

 