Place of Origin: | China |
Brand Name: | Triumph |
Certification: | CE ISO FDA |
Model Number: | TR-1 |
Minimum Order Quantity: | 1pc |
---|---|
Price: | Negotiable |
Packaging Details: | 1pc/carton 28KG/Carton |
Delivery Time: | 1 day After Got Payment |
Payment Terms: | L/C, D/A, D/P, T/T, , MoneyGram |
Supply Ability: | 500pcs/Month |
Working Pressure: | 134 Degree | Voltage: | 110V / 220V |
---|---|---|---|
Weight: | 28kg | Capacity: | 18L |
Wrranty: | 1Year | After Sale Service: | Online Technical Support |
High Light: | SS Dental Autoclave Sterilizer,18L Dental Autoclave Sterilizer,134 Degree Medical Steam Sterilizer |
USA Apixia Dental X Ray Machine PSP 3D Scanner
Specification:
Chamber capacity Ø 250XD350MM
Inside capacity 18L
Outside size 60*39*36
Sterlize temperature 122º C &132º C
Sterilize Pressure (Mpa) 0.12Mpa & 0.23Mpa
Sterilize Time 25Min & 6Min
No dry function
Heater 1000W
Material Quality Stainless Steel SUS#304 Boiler chamber surface with burnish
Surface deal with the machine foundation and the shell use high temperature baking varnish processing
Electric current 110V9A, 220V 4.5A
Manual give the water
Name of Each Part
1.Pressure gauge
2.Error indicator
3.134C light
4.Door bolt
5.Temp selector switch
6.Power switch
8.Steam discharge switch
9.Door handle
Size | 64×46×41cm |
Feature | Economic Style |
Application | Dental Areal |
Voltage | 220V,50Hz or 110V,60Hz |
Use Step:
Step 1:pouring the 800ml Distilled water into the chamber.
Step 2:will need the sterilization instrument to put in the tray.
Step 3:Closed the door and insert the bolt
Step 4:Close the steamexhaust switch.
Step 5:Select the temperature you need to (121℃or134℃)
Step 6:Turns on the POWER switch.(starts to work
Disinfect Process
Heating
----First emissions steam
----Second emissions steam
-----The temperature rise arrives at the disinfection temperature
----Starts to disinfect
----The disinfection completes
----Buzzer sound
-----The buzzer stops the sound
-----Turns on the steam emissions switch
----Waited for that the Pressure gauge nulling operation
----Waits for 6~8 minutes
----Opens the door
----The disinfection completes
When the door cannot open.
1: don't hard revolving door cover handle.
(if the hard rotating handle, will cause machine damage.)
2: the solution:
find the machine safety valve in the rear of the TAB,
pull the TAB out about3 ~ 4 minutes after let go.
Can rotate handle turnstiles cover to move.
Caution:
1.After the completion of disinfection. Please to wait for 10 ninutes.
Belore open the DOOR(Do not close the power switch and close the steam
emissions switch).
2.Before each use. Must supply water 800ml. (Distilled water is the
bast)
3.Pleaso closo steam missions switch. Before In the disinfection.
4.Do not use any corrosive or chemical water as the disinfectlon.
5.Do not share the same electricoutlet with other electrical apparetus.
6.Please pay attention to correct voltage and frequency.
7.Connect steam exhaust pipe with the steam vent, Before operation.
Trouble Shooting:
When disinfection work has not completed,the buzzer makes a sound and
the Error indicator twinkle.Please to check: Turns on the emissions steam
switch.machine steam and pressure emissions.(Do not off the power
switch,turns on the steam switch first)10 minutes later opens the machine
door.(Very important)
Condlton 1:Check the disinfection room to have the sufficient water
surce.Temperature protection switch work stop heating pipe work. (Wait for
15min later,lest the temperature protection switch restore normally.Joins
the water source, before each time uses the machineJoins 800ml.)(Doing
2-3 times ofandon the power switch movementafter. Turns on the powor
switch,machine to work)
Condltlon 2:Sudden power falure(Turn off and on the power swutch 2~3
tlmes.machine to normal work.
Condltlon 3: Can openthe door cover. 1-1 completion ofdisinfection.
afterwork. Hearbuzzersounded. 1 2.The firstopenthe steamswitch.Let
steam discharge. 1-3.Open the door cover. 1-4.Turn off the power switch
CondHon 4: The fllowing code shows.E1 and E4 (high temperature.
Reason:CHAMBER inside water enough. Solution: open the door cover,
wait for 5 minutes. Add water. Repeat off and turn on the power switch 2.)E3
(reason: the machine is in operation, power failure or instabillty. Solution:
repetition and opens and closes thepower switch 2time.
Contact Us:
DepartmentDaisy Dai(Ms)/Export
Linker Dental Group Limited
Web: www.zzlinker.com
Skype: zzlinker3
Email: [email protected]
Mobile/whatsapp/wechat:0086 13849058625
Contact Person: Daisy Dai
Tel: +8613849058625
Surgical Dental Diamond Burs Tooth Polishing FG Type High Speed Handpiece Support
210pcs Sample Bur Book FG Diamond Head With Calculator Exhibition Dentist Supply
Disposable Dental Abrasive Polishing Natural Rubber Material Prophy Cup RA 100pcs/box
Opening Type Dental Abrasive Bur Disinfection Box 30 holes Colorful FG RA
Led Light Professional Laser Teeth Whitening Machine Blue color Wheeled Easy Install
Zoom Teeth Whitening Unit Red Color Lighting 300W 40-50cm Clamping Poweful
Dental Teeth Whitening Led Lamp Cold Light 18V Irradiation Two Or Three Times Each Course
35% Hydrogen Peroxide Whitening Gel , At Home Teeth Whitening Gel Dental Professional Strength
Protaper Dental Gutta Percha Points , Dental Absorbent Paper Points F1 F2 F3 Universal
GP Protaper Paper Points For Dentistry Gutta Percha Dental Filling Millimeter Marked
Protaper Gutta Percha Root Canal Filling Material Rubber Based Dentistry Support
Like Waveone Dental Gutta Percha Points , Protaper Gp Points Dental F1 F2 F3 Sizes Available